DECKER ENGINEERING
Div. of Decker Air Controls, Inc.

Email:info@deckerairlogic.com

Home  Back  Next  Prices

Circuit Integration / Reduction Aids

1013
THREE-INPUT OR

Inputs at 1 "or" 2 "or" 3 results in an output at 4. Output pressure will be the highest of the inputs present.

1014
THREE-INPUT AND

Simultaneous inputs at 1 "and" 2 "and" 3 results in an output at 4. Output pressure will be weakest of the three inputs.

1022
YOR MODULE

Supply pressure 1 becomes output 4 when wither of pilots 2 or 3 are present.

1016
INHIBITED OR

Inputs at 1 "or" 2 will result in an output at 4 unless pilot 3 is present. The output pressure will be the greater of inputs 1 or 2.

1017
FOUR-WAY
MOMENTARY

When supply 1 is present and pilot 2 is not present, supply 1 is output at 3. Application of pilot 2 shifts the supply to output 4 for so long as the pilot signal is present. Dropping pilot 2 re-directs the output to 3.

1018
AND/OR MODULE

Inputs at 1 "or" 2 result in an output at 3. Simultaneous application of inputs 1 "and" 2 results in an additional and concurrent output at 4.

1019
NOT/NOT MODULE

Inputs 1 and 2 "race." If input 1 wins, it becomes an output at 3 for so long as it is maintained, regardless of whether input 2 arrives; if input 2 wins, input 1 is inhibited from becoming an output.

Pressure- / Position-Sensing Elements

1027
PRSSURE RELEASE
TRIP VALVE

Essentially the same as 1004 "Not" element with modified shift specifications in order to facilitate end-of-stroke sensing. Internal flow passages 0.060" equivalent.



Home | Basic Elements | Integrated Modules - Memory Circuits
Integrated Modules - Boolean Functions | Circuit Integration / Reduction Aids
Pressure/Position-Sensing Elements | Timing Modules | Specialty Integrated Cirucits
Mounting Plate Information | Price List